Skip to content
LOS Analyzer

Building · 2026

199 Shepard Freezer Addition

Wheeling, IL · near Chicago Exec (1.2 mi)

Determination of no hazardDetermined - No Hazard53 ft AGL

What this outcome means

The FAA studied the proposal and concluded it would not be a hazard to air navigation. A no-hazard determination is not permanent — it carries an expiration date, and if the structure is not built by then the case has to be re-filed.

The proposal, in the filer's words

"The project is a building addition and is a freezer constructed of insulated metal building panels against an existing precast concrete panel warehouse - The top of the addition is 46 feet above the finished floor - finished floor elevation is 644-85 feet - Rooftop screening is required and the top of that is approximately 53 feet above the finished floor - This addition is located on the southeast side of the building and runs in the east-west direction - The addition is 211 feet long by 86-5 feet wide on the east end and is 63-5 feet wide against the existing building and maintains that width for 151 feet to the east - There will be a crane during construction approximately 60 feet tall"

Filing details

Case number (ASN)
2026-AGL-9828-OE
Structure
199 Shepard Freezer Addition
Type
Building
Category
Building
Height above ground
53 ft
Height above sea level
697 ft
Site elevation
644 ft
Notice of
New Construction
Duration
Permanent
Marking & lighting
—

Timeline

Filed
June 15, 2026
Determined
August 21, 2026
Determination expires
February 21, 2028

A determination that lapses before the structure is built has to be re-filed. The FAA does not send a reminder.

Who filed it

Sponsor
JV Global
Representative
Harris Architects Inc

Names are shown as they appear in the FAA's public record. How we handle names

Location

Coordinates
42.126508, -87.920269
Degrees / minutes / seconds
42°07'35.4"N 87°55'13.0"W
County
Cook

Other filings within 5 miles

Organisation-sponsored 2026 filings whose coordinates sit near this one.

See every 2026 filing near Chicago Exec →

About this record

This page is a readable copy of a public record published by the FAA's Obstruction Evaluation / Airport Airspace Analysis system. It is not the official record and may lag it. For the authoritative case status, search this ASN at the FAA's OE/AAA portal. If something here is wrong, email support@idea-engine.studio and we will correct it.

Source: FAA Obstruction Evaluation / Airport Airspace Analysis (OE/AAA) public archive (oeaaa.faa.gov), data as of September 12, 2026. Compiled by LOS Analyzer (Idea Engine LLC). This is not an official FAA record or an FAA determination; the FAA's portal is authoritative. LOS Analyzer is not affiliated with or endorsed by the FAA.

Screening a structure of your own?

Check Part 77 and the tower's line of sight before you file

LOS Analyzer screens a proposed structure against FAA Part 77 surfaces and the control tower's sightline to the runway, terrain-aware, in minutes. It is a preliminary screening — not an FAA determination and not a substitute for a licensed engineering review.