Skip to content
LOS Analyzer

Antenna tower · 2026

WPB Outdoor Wi-Fi Extension project

West Palm Beach, FL · near Palm Beach Intl (0.8 mi)

Returned to proponentDetermined - No Hazard25 ft AGL

What this outcome means

The FAA sent the case back to the filer rather than issuing a determination. This is the most common non-clean outcome and usually means something has to change or be supplied before the study can finish — not that the project was refused.

The proposal, in the filer's words

"Add 25-30ft Pole\nInstall Outlet at base of pole\nAdd IDF Cabinet + grounding bar inside cabinet\n*Take photo of label on side of Switch for cabling hookups* \n(Mount Switch and PSU on DIN rail before installing rail into cabinet on line 2)\n*Ground cable to switch and PSU should be 10-12 AWG*\n*Power whip to PSU should be 14 AWG twisted pair*\n*2-Pair Power cables from PSU to Switch should be 16-18 AWG twisted pair\nRun 3 outlet extension cord up into Cabinet (plug in Temp Fan and power whip for Switch Power Supply).\n3 RJ45 Lightning Suppressors will be placed inside the cabinet. Grounding from them to the grounding bar inside the cabinet.\n1 for the MeshPoint and 2 for the APs \nAdd Point to Point MeshPoint near the top (Screw two antennas on top) *Rough point toward the MeshEnd on the Building. Fine aiming will happen once there online.\n*Add AP-1 about 4 ft below the PtP with mount AIR-MNT-ART1= (Angle Down 20*) \nSo patch cables from the switch to the RJ45 Lightning Suppressors and then patch cable from them out to the PtP and APs."

Filing details

Case number (ASN)
2026-ASO-1576-NRA
Structure
WPB Outdoor Wi-Fi Extension project
Type
Pole / mono
Category
Antenna tower
Height above ground
25 ft
Height above sea level
38 ft
Site elevation
13 ft
Notice of
New Construction
Duration
Permanent
Marking & lighting
—

Timeline

Filed
March 9, 2026
Determined
April 29, 2026
Determination expires
October 29, 2027

A determination that lapses before the structure is built has to be re-filed. The FAA does not send a reminder.

Who filed it

Sponsor
Gulfstream Aerospace Corp
Representative
Sarah Krueger

Names are shown as they appear in the FAA's public record. How we handle names

Location

Coordinates
26.685798, -80.109003
Degrees / minutes / seconds
26°41'08.9"N 80°06'32.4"W
County
Palm Beach

Other filings within 5 miles

Organisation-sponsored 2026 filings whose coordinates sit near this one.

See every 2026 filing near Palm Beach Intl →

About this record

This page is a readable copy of a public record published by the FAA's Obstruction Evaluation / Airport Airspace Analysis system. It is not the official record and may lag it. For the authoritative case status, search this ASN at the FAA's OE/AAA portal. If something here is wrong, email support@idea-engine.studio and we will correct it.

Source: FAA Obstruction Evaluation / Airport Airspace Analysis (OE/AAA) public archive (oeaaa.faa.gov), data as of September 12, 2026. Compiled by LOS Analyzer (Idea Engine LLC). This is not an official FAA record or an FAA determination; the FAA's portal is authoritative. LOS Analyzer is not affiliated with or endorsed by the FAA.

Screening a structure of your own?

Check Part 77 and the tower's line of sight before you file

LOS Analyzer screens a proposed structure against FAA Part 77 surfaces and the control tower's sightline to the runway, terrain-aware, in minutes. It is a preliminary screening — not an FAA determination and not a substitute for a licensed engineering review.