Skip to content
LOS Analyzer

Crane · 2026

Construction Crane: Kwik Trip EV Canopy

Albert Lea, MN · near Albert Lea Muni (0.4 mi)

Determination of no hazardDetermined - No Hazard150 ft AGL

What this outcome means

The FAA studied the proposal and concluded it would not be a hazard to air navigation. A no-hazard determination is not permanent — it carries an expiration date, and if the structure is not built by then the case has to be re-filed.

The proposal, in the filer's words

"Kwik Trip proposes the installation of a full NEVI-enabled Konect charging system providing a maximum of 600kW across four total chargers. The project location and site details can be found throughout the attached maps in the Appendix with clear site delineation in the Overall Site Plan.  \nIn addition to the chargers Kwik Trip proposes to do the following:  \n• Install one designated EV stall for each charger (four total) each with EV pavement markings. Two of these stalls will be ADA-compliant stalls to accommodate all types of EVs.  \n• Install a 20-foot by 45-foot canopy above the proposed chargers and stalls. Canopy height is expected to be 16 feet above the ground with excavation 48 in. deep for canopy foundations. \n• Install a pad-mounted electrical utility transformer. The transformer will require the addition of switchgear conduit and wiring to the site. Freeborn Mower Electric Cooperative—the location’s energy provider—has confirmed their ability to provide these upgrades.  \n• Install wayfinding signage directing divers to the chargers.  \n• Install switchgear with precast concrete foundation.  \n• Construct deterrent bollards to protect the chargers from vehicle collisions.  \n• Place trash can recycling and squeegee station atop a concrete pad.  \n• Install a fire extinguisher and cabinet.  \n• Install a security camera.  \n• Excavate 1 200 sq ft of material with a maximum depth of 36 in. for conduit. \n \nThe proposed transformer will require an estimated 1 200 square feet of material will be excavated for conduits to be installed 31 inches below grade for a full excavation depth of 35 to 36 inches. Foundations for the proposed canopy will require excavation approximately 48 inches below work. All other work will be aboveground on preexisting paved asphalt on Kwik Trip owned property. The proposed action will take place on the southern portion of the property adjacent to the property boundary separating it from an automotive dealership. Just north of this aboveground work will be an area of excavation to install conduits for chargers and directional bore feeders from Freeborn Mower Electric Cooperative."

Filing details

Case number (ASN)
2026-AGL-1146-OE
Structure
Construction Crane: Kwik Trip EV Canopy
Type
Crane / mobile
Category
Crane
Height above ground
150 ft
Height above sea level
1,405 ft
Site elevation
1,255 ft
Notice of
New Construction
Duration
Temporary
Marking & lighting
Red lights and flags

Timeline

Filed
January 13, 2026
Determined
February 18, 2026
Determination expires
August 18, 2027

A determination that lapses before the structure is built has to be re-filed. The FAA does not send a reminder.

Who filed it

Sponsor
Minnesota Department of Transportation
Representative
WSP USA

Names are shown as they appear in the FAA's public record. How we handle names

See every 2026 filing by Minnesota Department of Transportation →

Location

Coordinates
43.683246, -93.360024
Degrees / minutes / seconds
43°40'59.7"N 93°21'36.1"W
County
Freeborn

Other filings within 5 miles

Organisation-sponsored 2026 filings whose coordinates sit near this one.

About this record

This page is a readable copy of a public record published by the FAA's Obstruction Evaluation / Airport Airspace Analysis system. It is not the official record and may lag it. For the authoritative case status, search this ASN at the FAA's OE/AAA portal. If something here is wrong, email support@idea-engine.studio and we will correct it.

Source: FAA Obstruction Evaluation / Airport Airspace Analysis (OE/AAA) public archive (oeaaa.faa.gov), data as of September 12, 2026. Compiled by LOS Analyzer (Idea Engine LLC). This is not an official FAA record or an FAA determination; the FAA's portal is authoritative. LOS Analyzer is not affiliated with or endorsed by the FAA.

Screening a structure of your own?

Check Part 77 and the tower's line of sight before you file

LOS Analyzer screens a proposed structure against FAA Part 77 surfaces and the control tower's sightline to the runway, terrain-aware, in minutes. It is a preliminary screening — not an FAA determination and not a substitute for a licensed engineering review.